MAVIN Loadcell OIML C3 Approved High Accuracy Single Point Sensor
Specifications
Details
MAVIN Loadcell OIML C3 Approved High Accuracy Single Point Load Cell Sensor – Precision for Pricing & Counting Scales
MAVIN Loadcell OIML C3 Approved High Accuracy Single Point Load Cell Sensor is engineered to provide exceptional precision for a wide range of weighing applications. This advanced High Accuracy Load Cell C3 is perfect for pricing scales, counting scales, and various other retail and industrial weighing solutions. Featuring the OIML C3 Accuracy Class, this load cell ensures reliable performance, meeting the stringent standards for high-precision measurements.
The NA1 Load Cell is a single-point load cell made of durable aluminium alloy, ensuring both lightweight construction and high reliability. Calibrated to national standards, the MAVIN load cell is available in higher accuracy versions for more specialized applications. With an easy-to-install design and exceptional robustness, this load cell is ideal for demanding environments and accurate weight measurement needs.
Specifications:
- Accuracy Class C3: Ensures high precision and reliability
- Calibrated to National Standards: Meets stringent quality standards for accuracy
- Aluminum Alloy Construction: Lightweight, durable, and corrosion-resistant
- Easy to Install: Designed for hassle-free integration into your scale system
Dimension:
NA1 Specifications:
Rated Capacities | 3~50 (kg) |
Rated Output | 2.0 mV/V±10% |
Zero Balance | ±0.0200 mV/V |
Accuracy class | OIML C3 |
Max No.of loadcell interval(nmax) | 3000 |
Min No.of loadcell interval(Vmin) | Emax/7000 |
Non-linearity | 0.017 %R.O. |
Hysteresis | 0.017 %R.O. |
Repeatability | 0.017 %R.O. |
30mins Creep | 0.017 %R.O. |
30mins Return | 0.017 %R.O. |
Safe Overload | 150 %R.O. |
Ultimate Overload | 200 %R.O. |
Temperature Effect On Output | 0.0015 %R.O./℃ |
Temperature Effect On Zero | 0.002 %R.O./℃ |
Input Impedance | 410±15 Ω |
Output Impedance | 350±5 Ω |
Insulation Impedance | ≥5000 MΩ/(50VDC) |
Recommended Excitation | 5~12 VDC |
Maximum Excitation | 15 VDC |
OperatingTemperatureRange | -20~60 ℃ |
Construction | Aluminum Alloy |
Protection Class | IP66 / IP67 |
Cable | φ4×0.5m |
Recommended Platform Size | 350×400 mm |
Mode of Connection | Red(EXC+),Black(EXC-),Green(SIG+),White(SIG-) |
View more about MAVIN Loadcell OIML C3 Approved High Accuracy Single Point Sensor on main site